47
GasAlertMicroClip XT
Maintenance
Battery Cautions
a Warning
To avoid personal injury and/or property damage, adhere to
the following:
• The detector must be deactivated to charge the battery.
• Charge the battery immediately when the detector emits a low
battery alarm. Refer to Charging the Battery
.
• Charge the battery in a safe area that is free of hazardous gas
in temperatures of 32°F to 113°F (0°C to 45°C).
• Charge the battery using the BW Multi-Unit Cradle Charger or
charger adapter only. Do not use any other charging adapters.
Failure to adhere to this caution can lead to fire and/or explo-
sion.
• The charging adapter is voltage specific to your region. Use of
the charging adapter outside your region will damage the
charger and the detector.
• Do not calibrate the detector during or immediately after
charging the battery.
• The battery can only be replaced by the manufacturer. Failure
to adhere to this caution can lead to fire and/or explosion.
• Warning: The GasAlertMicroClip XT uses a lithium battery that
may present a risk of fire or chemical burn hazard if misused.
Do not disassemble, heat above 212° (100°C), or incinerate.
• Warning: Lithium polymer cells exposed to heat at 266°F
(130°C) for 10 minutes can cause fire and/or explosion.
Charging the Battery
To charge the battery, refer to Figure 10., Table 12., and the following
procedures (1-8).
Figure 10. Connecting the Charging Adapter
Kommentare zu diesen Handbüchern