GasAlertMicroClip XT
Technical Reference Guide
34
Clearing Gas Exposures
a Caution
Follow all safety procedures as defined by your employer.
Confirm with your supervisor before clearing TWA and STEL
alarms.
To clear the TWA, STEL, and peak exposure readings, press C when
the LCD displays RESET.
Gas Alarm Setpoints
Gas alarms are activated when detected gas concentrations are above
or below the user-defined setpoints. Gas alarms are described below.
Table 9. Gas Alarm Setpoints
Alarm Condition
Low
Toxics and combustibles: Ambient gas
level above low alarm setpoint.
Oxygen: Ambient gas level may be set
above or below 20.9% (or 20.8%).
High
Toxics and combustibles: Ambient gas
level above high alarm setpoint.
Oxygen: Ambient gas level may be set
above or below 20.9% (or 20.8%).
TWA
Toxi cs only : Accumulated value above
the TWA alarm setpoint.
STEL
Toxi cs only : Accumulated value above
the STEL alarm setpoint.
Downscale
Toxi cs only : If sensor reading is
negative (half of the TWA setpoint)
Multi-gas Two or more gas alarm conditions.
Over Limit (OL)
OL displays when readings are above
or below the sensor detection range.
Refer to Specifications
for detection
ranges.