BW Technologies MicroClip XT Spezifikationen Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
3
GasAlertMicroClip XT
a
Cautions
a Cautions
Warning: Substitution of components may impair Intrinsic Safety.
Before using the detector, refer to Sensor Poisons and Contaminants
.
Warning: For safety reasons, this equipment must be operated and serviced by qualified personnel only. Read and understand the
user manual completely before operating or servicing.
Do not use the detector if it is damaged. Inspect the detector before using. Look for cracks and/or missing parts.
If the detector is damaged or parts are missing, contact BW Technologies by Honeywell
immediately.
Only use sensor(s) that are specifically designed for the GasAlertMicroClip XT. Refer to Replacement Parts and Accessories
.
Calibrate the detector before first-time use and then on a regular schedule, depending on use and sensor exposure to poisons and
contaminants. BW recommends calibrating at least once every 180 days (6 months).
BW recommends to “bump test” the sensors before each day’s use to confirm their ability to respond to gas by exposing the
detector to a gas concentration that exceeds the alarm setpoints. Manually verify that the audible and visual alarms are activated.
Calibrate if the readings are not within the specified limits.
BW recommends the combustible sensor be checked with a known concentration of calibration gas after any known exposure to
catalyst contaminants/poisons (sulfur compounds, silicon vapors, halogenated compounds, etc).
The combustible sensor is factory calibrated to 50% LEL methane. If monitoring a different combustible gas in the % LEL range,
calibrate the sensor using the appropriate gas.
Caution: High off-scale readings may indicate an explosive concentration.
Only the combustible gas detection portion of this instrument has been assessed for performance by CSA International.
Protect the combustible sensor from exposure to lead compounds, silicones, and chlorinated hydrocarbons.
Sensor exposure to certain organic vapors (such as leaded gasoline and halogenated hydrocarbons) may temporarily inhibit sensor
performance. After exposure, a bump test or calibration is recommended.