Replacing the sensor filter
1. Note the placement of the PCB to ensure it is
replaced correctly. Remove the two screws on the
PCB. Remove the PCB carefully.
a
Caution
Ensure no damage occurs to the battery.
2. Remove the old sensor filter. It may be stuck to the
sensors.
3. Place the new sensor filter.
Note
When inserting a new sensor filter, ensure the black
gasket is facing the front shell.
4. To complete the detector, refer to Reassembling the
detector.
Replacing H
2
S, CO, and LEL sensor
1. Note the placement of the PCB to ensure it is
replaced correctly. Remove the two screws on the
PCB. Remove the PCB carefully.
a
Caution
Ensure no damage occurs to the battery.
If the sensor filter is stuck to the sensors, remove and
replace the sensor filter into the front shell.
2. Slide the sensors out.
Note
Detectors that are configured for 1, 2, or 3 gases may
contain a dummy sensor in one of the four sensor
locations.
3. Insert the new sensor(s).
4. To complete the detector, refer to Reassembling the
detector.