4. Press D or E to scroll to a new user option or
press C to exit and return to normal operating
mode.
Automatic Backlight Option
The automatic backlight (BKLT) option is used to enable or
disable the automatic backlight of the detector. When
enabled, the backlight automatically turns on for 3 seconds
whenever there is insufficient light to view the LCD.
Press and hold (until backlight activates) any button to
activate the backlight for 6 seconds.
Note
The detector is shipped with the automatic
backlight option enabled. Backlight does not
operate while in stealth mode.
To enable/disable the automatic backlight, complete the
following:
1. From the EXIT screen of the user options menu,
use D or E to scroll to the BKLT option.
2. Press C to accept the option. The LCD flashes
either ON or OFF.
3. Press D or E to toggle between the ON/OFF
options. Ensure the desired option is displayed
and press C to confirm the selection.
The LCD returns to the EXIT screen.
Note
The BKLT option is not available in the user
options menu while stealth mode is enabled.
4. Press D or E to scroll to a new user option or
press C to exit and return to normal operating
mode.